ICM Part Numbers |
||||||||
|
Manufacturer |
Product Item Number |
Description |
|||||||
|
ICM |
ACC-OE-01 |
WEATHERPROOF ENCLOSURE |
|||||||
|
ICM |
ACC-OE-03 |
WEATHERPROOF ENCLOSURE |
|||||||
|
ICM |
ACC-RT104 |
REMOTE SENSOR FOR SC3801 |
|||||||
|
ICM |
ACC-WIH21 |
Master to Tagret
Cable SC |
|||||||
|
ICM |
ACC-WP03 |
Universal Large Wall Plate |
|||||||
|
ICM |
ACC-WP04 |
Universal Small Wall Plate |
|||||||
|
ICM |
ACS-11 |
11PIN RLY SCKT,ICM410-27&500-0 |
|||||||
|
ICM |
ACS-8 |
8PIN RLY SCKT,ICM410-27&500-05 |
|||||||
|
ICM |
AMS120A180 |
180SEC FIXED DELAY, 120V |
|||||||
|
ICM |
AMS24A300 |
ANTI-SHORT CYCLE CTRL |
|||||||
|
ICM |
BES115A1X5A |
T-5R,115V 5SEC TIME DELAY |
|||||||
|
ICM |
BES24A1X5A |
T5R-24V, 5SEC TIME DELAY 24V |
|||||||
|
ICM |
BMS115A1X20 |
120V 20S DELAY ON BREAK TIMER |
|||||||
|
ICM |
BMS230A1X60 |
230V,60S,DELAY-ON-BREAK TIMER |
|||||||
|
ICM |
CC750-115 |
115V Blower Speed Control |
|||||||
|
ICM |
CC750-230 |
230V Blower Speed Control |
|||||||
|
ICM |
FS1500L |
GarageStat,35F-75F,HtgOnly |
|||||||
|
ICM |
FS1500VL |
GarageStat,35F-75F,HtOnly,Vert |
|||||||
|
ICM |
FS40 |
GarageStat,FixedSetPoint,40F |
|||||||
|
ICM |
HBVR115A2X300 |
POST PURGE TIMER |
|||||||
|
ICM |
HMVR24A2Y05 |
DELAY ON MAKE 1-100MIN ADJ 24V |
|||||||
|
ICM |
ICM100F |
18-30VAC/DC 3MIN DELAY/MAKE |
|||||||
|
ICM |
ICM100 |
18-30VAC/DC 3 MIN DELAY/MAKE |
|||||||
|
ICM |
ICM101F |
18-30VAC/DC 5MIN DELAY/MAKE |
|||||||
|
ICM |
ICM101 |
5 MIN DELAY ON MAKE TIMER |
|||||||
|
ICM |
ICM102F |
10MinAdjDelay/Make 6"WireTerm |
|||||||
|
ICM |
ICM102 |
.1-600secDelayOnMakeTimer |
|||||||
|
ICM |
ICM103 |
1-1,023secs,SwtchSetbl;DlyMake |
|||||||
|
ICM |
ICM104 |
DELAY ON MAKE 10-1000 SEC ADJ |
|||||||
|
ICM |
ICM105 |
DelayOnMake 10min ADJUSTABLE |
|||||||
|
ICM |
ICM1501 |
OilPrimaryControl,15secLockout |
|||||||
|
ICM |
ICM1502 |
OilPrimaryControl,30SecLockout |
|||||||
|
ICM |
ICM1503 |
OilPrimaryControl,45SecLockout |
|||||||
|
ICM |
ICM150 |
RandomStartTimer,10minAdj |
|||||||
|
ICM |
ICM1512 |
OIL PRIMARY 15SEC INTERRUPTED |
|||||||
|
ICM |
ICM151 |
RandomStartTimer,.1/600secSPST |
|||||||
|
ICM |
ICM175 |
1000sec BYPASS TIMER, ADJ. |
|||||||
|
ICM |
ICM200F |
3MIN DelayOnBreak
W/6"WireTerm |
|||||||
|
ICM |
ICM200 |
18-30VAC 3MIN DELAY ON BREAK |
|||||||
|
ICM |
ICM201F |
5MIN FIXED W/6"WIRE DLY ON
BRK |
|||||||
|
ICM |
ICM201 |
5 MIN.FIXED DELAY ON BREAK |
|||||||
|
ICM |
ICM203F |
10MIN ADJ W/6"WIRE DLY ON BRK |
|||||||
|
ICM |
ICM203 |
DELAY ON BREAK,.03-10min.adj. |
|||||||
|
ICM |
ICM204 |
3minDelayOnBreakTimeDelay |
|||||||
|
ICM |
ICM205 |
5min DelayOnBreakTimeDelay
|
|||||||
|
ICM |
ICM206 |
RELAY,DELAY
ON BREAK 10minADJ. |
|||||||
|
ICM |
ICM207 |
DELAY ON BREAK,3min FIXED |
|||||||
|
ICM |
ICM208 |
DelayOnBreak5minFixUnivVoltage |
|||||||
|
ICM |
ICM209 |
DelayOnBreak10minAdjUnivVolt |
|||||||
|
ICM |
ICM210 |
DUAL FUNC,DELAY ON MAKE |
|||||||
|
ICM |
ICM211 |
DelayOnBreak5min,ASC TimeDelay |
|||||||
|
ICM |
ICM212 |
DUAL FUNC,DELAY ON MAKE |
|||||||
|
ICM |
ICM220 |
LOCKOUT RELAY, 18-30VAC |
|||||||
|
ICM |
ICM221 |
24V COMPRESSOR PROTECTION BRD |
|||||||
|
ICM |
ICM222 |
24v LockoutProtectionMod |
|||||||
|
ICM |
ICM251 |
20AMP,DUAL ON/OFF DELAY,ADJ. |
|||||||
|
ICM |
ICM253 |
DELAYonBRK TIMER,12-390sec24V |
|||||||
|
ICM |
ICM254 |
ON&OFF DELAY on1/180off12/390 |
|||||||
|
ICM |
ICM255 |
PostPurgeFanDelay 1/180sec |
|||||||
|
ICM |
ICM270 |
FAN BLOWER CTRL,DUAL FUNC |
|||||||
|
ICM |
ICM271 |
DUAL FUNC.TIME DELAY |
|||||||
|
ICM |
ICM272 |
FAN BLOWER CONTROL |
|||||||
|
ICM |
ICM273 |
FAN BLOWER CONTROL |
|||||||
|
ICM |
ICM274 |
FAN BLOWER CTRL |
|||||||
|
ICM |
ICM275 |
FAN BLOWER CTRL |
|||||||
|
ICM |
ICM277 |
FAN BLOWER CONTROL |
|||||||
|
ICM |
ICM2801 |
York/Evcon
Repl Control Board |
|||||||
|
ICM |
ICM2804 |
Furnace Control Board |
|||||||
|
ICM |
ICM2805A |
Furnace Control Board |
|||||||
|
ICM |
ICM280 |
Furnace Control Board |
|||||||
|
ICM |
ICM281 |
FURNACE CONTROL MODULE |
|||||||
|
ICM |
ICM282A |
Circuit Board and Plug Kit |
|||||||
|
ICM |
ICM283 |
Repl HSI Module |
|||||||
|
ICM |
ICM284 |
FIXEDSPEED FURNACE CTRL MODULE |
|||||||
|
ICM |
ICM286 |
Furnace Control Module |
|||||||
|
ICM |
ICM287 |
Furnace Control Module |
|||||||
|
ICM |
ICM289 |
Furnace Control Board |
|||||||
|
ICM |
ICM2901 |
IPI Gas Ignition Control |
|||||||
|
ICM |
ICM2902 |
IPI Gas Ignition Control |
|||||||
|
ICM |
ICM290A |
IPI Gas Ignition Control |
|||||||
|
ICM |
ICM291 |
Repl HSI Control Board |
|||||||
|
ICM |
ICM292 |
Repl Rheem DSI Cntrl
Board |
|||||||
|
ICM |
ICM293 |
OEM REPLACEMENT BOARD |
|||||||
|
ICM |
ICM294 |
24v,NoPP,85secTFI,Intermittent |
|||||||
|
ICM |
ICM295 |
IPI Gas Ignition Control |
|||||||
|
ICM |
ICM296 |
IPI Gas Ignition Control |
|||||||
|
ICM |
ICM300 |
30/60/90min 24vac DEFROST TMR |
|||||||
|
ICM |
ICM301 |
30/60/90MIN DEFROST TIMER |
|||||||
|
ICM |
ICM302 |
30/60/90 MIN DEFROST TIMER |
|||||||
|
ICM |
ICM303 |
30/60/90 MIN DEFROST TIMER |
|||||||
|
ICM |
ICM304 |
30/60/90 MIN DEFROST TIMER |
|||||||
|
ICM |
ICM305 |
DUTY CYCLE CTRL,ADJ TIME DELAY |
|||||||
|
ICM |
ICM306 |
DUTY CYCLE CTRL,1-1023 SEC |
|||||||
|
ICM |
ICM307 |
30/60/90 MIN DEFROST CONTROL |
|||||||
|
ICM |
ICM309 |
FreezeProtectionMod 28fcu55ci |
|||||||
|
ICM |
ICM310 |
FreezeProtectionMod 44fcu48ci |
|||||||
|
ICM |
ICM315 |
PIN-SELECTABLE,30/45/90 MIN. |
|||||||
|
ICM |
ICM316 |
50/70/90 MIN DEFROST TIMER |
|||||||
|
ICM |
ICM318 |
30/60/80 MIN DEFROST TIMER |
|||||||
|
ICM |
ICM319 |
30/60/90 MIN DEFROST TIMER |
|||||||
|
ICM |
ICM320 |
PIN-SELECT.30/50/90 MIN TIMER |
|||||||
|
ICM |
ICM321 |
30/50/90 MIN DEFROST TIMER |
|||||||
|
ICM |
ICM322 |
30/50/90 MIN DEFROST TIMER |
|||||||
|
ICM |
ICM324 |
CONDENSATE CONTROL |
|||||||
|
ICM |
ICM325HNV |
HeadPressureControl 70/100f |
|||||||
|
ICM |
ICM325HN |
120to480vOut Head#W/HtPumpByps |
|||||||
|
ICM |
ICM326HM |
Head#W/HtPmpBypsW/Probe120/240 |
|||||||
|
ICM |
ICM326HN |
120/208/240V HEAD PRESSURE CNT |
|||||||
|
ICM |
ICM327HN |
480vOUT Head#W/HtPumpBypass |
|||||||
|
ICM |
ICM330 |
Head#Ctrl 120-480vacOut 24vIN |
|||||||
|
ICM |
ICM333 |
DualInputHead#Ctrl,120-600vac |
|||||||
|
ICM |
ICM340 |
18-30V CondensationCtrl |
|||||||
|
ICM |
ICM342 |
CONDENSATE SWITCH |
|||||||
|
ICM |
ICM345 |
CONDENSATION CONTROL W/ALARM |
|||||||
|
ICM |
ICM375 |
PROBE FOR "K"
SERIES,50-80F |
|||||||
|
ICM |
ICM376 |
HEAD # CtrlSensorProbe70/100F |
|||||||
|
ICM |
ICM377 |
KIT WITH 95-120F PROBE |
|||||||
|
ICM |
ICM379 |
PROBE,use w/ICM325H,326H &327H |
|||||||
|
ICM |
ICM380 |
OPT. # TRANS DUCE W/SHRAD FTNG |
|||||||
|
ICM |
ICM381 |
6-7' TEMP PROBE,ICM336/337 |
|||||||
|
ICM |
ICM400 |
3-PhaseLineMonitorAdj 190-600V |
|||||||
|
ICM |
ICM401 |
3phaseMont.190-600vacPhL&RevPr |
|||||||
|
ICM |
ICM402 |
3-PhaseLineMntr.,RVRSE PRTCTN |
|||||||
|
ICM |
ICM408 |
3PhaseLineMntrAdj190-480PlugIn |
|||||||
|
ICM |
ICM409 |
3PhaseLineMntrAdj190-480vDinRl |
|||||||
|
ICM |
ICM441 |
MOTOR PROTECTOR, W/DELAY |
|||||||
|
ICM |
ICM450 |
3-PHASE LINE MONITOR,PRGRMBL |
|||||||
|
ICM |
ICM491 |
95/270vacSPDT SinglePhVoltMont |
|||||||
|
ICM |
ICM492 |
MOTOR PROTECTOR |
|||||||
|
ICM |
ICM500-C-8 |
MULTI-MODE DIG TMR 8-PIN CONN |
|||||||
|
ICM |
ICM500D |
Multi-ModeDigTimer11PinBase24v |
|||||||
|
ICM |
ICM500 |
MULTI-MODE DIG TIMER 24V |
|||||||
|
ICM |
ICM501 |
MULTI-MODE DIG TIMER 115V |
|||||||
|
ICM |
ICM502 |
MULTI-MODE DIG TIMER 230V |
|||||||
|
ICM |
ICM503 |
MULTI-MODE DIGITAL TIMER 12VDC |
|||||||
|
ICM |
ICM504 |
MULTI-MODE, SWITCH SET, 24VDC |
|||||||
|
ICM |
ICM515 |
120/240V SURGE PROTECT 1 PHASE |
|||||||
|
ICM |
ICM600 |
LEAD-LAG CTL,BuiltInTstat,Encl |
|||||||
|
ICM |
ICM602 |
LEAD-LAG CONTROL,24vac |
|||||||
|
ICM |
ICM6100 |
FAN SAFETY ALARM CIRCUIT |
|||||||
|
ICM |
ICM705 |
240V ProgrammingBoardForGE
Mtr |
|||||||
|
ICM |
ICM706 |
120V ProgrammingBoardForGE
MTR |
|||||||
|
ICM |
ICM803 |
RAPID START KIT, 1-3HP CURRENT |
|||||||
|
ICM |
ICM805 |
RAPID START KIT, 3-5HP CURRENT |
|||||||
|
ICM |
ICM810 |
RAPID START KIT,5-10HP CURRENT |
|||||||
|
ICM |
ICM850 |
RAPID START KIT,1/12-1HP VOLT |
|||||||
|
ICM |
ICM855 |
PSC 1ph 1/2-10hp HardStartKit3 |
|||||||
|
ICM |
ICM856 |
PSC 1ph 1/2-10hp500%HardSrtKit |
|||||||
|
ICM |
ICM860 |
RAPID START KIT,1/2-1HP VOLT |
|||||||
|
ICM |
MAR115A1X240 |
115v FixedDelayOnMake
240sec |
|||||||
|
ICM |
MAR115A1X30 |
115v FixedDelayOnMake
30Sec |
|||||||
|
ICM |
MAR115A1X3 |
Delay on make 3sec |
|||||||
|
ICM |
MAR115A1X60 |
115v FixedDelayOnMake
60sec |
|||||||
|
ICM |
MAR115A1Y300 |
115v MAKE ON RISE FIXED 300sec |
|||||||
|
ICM |
MAR115A1Y30 |
115v MAKE ON RISE FIXED 30SEC |
|||||||
|
ICM |
MAR115A1Y60 |
10 AMP,60SEC FIXED, 115V |
|||||||
|
ICM |
MAR115A5X600 |
DELAY ON MAKE 4.8-600 SEC |
|||||||
|
ICM |
MAR230A5X100 |
DELAY ON MAKE 0/100 SEC |
|||||||
|
ICM |
MAR24A1X180 |
RELAY ON MAKE 24V 180 SEC. |
|||||||
|
ICM |
MDR115A7X5 |
TIME DELAY RELAY |
|||||||
|
ICM |
MES115A1X20A |
T-20, 20SEC TIME DELAY,115V |
|||||||
|
ICM |
MES115A1X30 |
TIME DELAY |
|||||||
|
ICM |
MES115A1X5 |
TIME DELAY RELAY |
|||||||
|
ICM |
MES115A1X60 |
TIME DELAY RELAY |
|||||||
|
ICM |
MES115A1Y4 |
115v 4-sec DELAY ON MAKE |
|||||||
|
ICM |
MES24A1X20A |
T20-24V 20sec DelayOnMake
24V |
|||||||
|
ICM |
MES24D1X20A |
T20-24VDC,20SEC TIME DELAY |
|||||||
|
ICM |
MLR115A2X600 |
TIME DELAY RELAY |
|||||||
|
ICM |
MLR115A4Z30 |
TIME DELAY |
|||||||
|
ICM |
MMS115A1X10B |
RELAY 120V |
|||||||
|
ICM |
MMS115A1X1B |
115V DELAY ON MAKE 1SEC |
|||||||
|
ICM |
MMS115A1Y10B |
FIXED RELAY |
|||||||
|
ICM |
MMS115A1Y60B |
FIXED RELAY |
|||||||
|
ICM |
MMS115A2X600 |
115V ADJ 600sec DELAY ON MAKE |
|||||||
|
ICM |
MMS115A5C480B |
RELAY |
|||||||
|
ICM |
MMS115A5Z480B |
115v DelayOnMake
Adj TIMER |
|||||||
|
ICM |
MMS230A1X240A |
DELAY ON MAKE TIMER |
|||||||
|
ICM |
MMS24A1X180A |
DELAY ON MAKE TIMER |
|||||||
|
ICM |
MMS24A1X240 |
FIXED DELAY, 24V |
|||||||
|
ICM |
MOR115A1Y35 |
35SEC DELAY ON MAKE, 115V |
|||||||
|
ICM |
MOR115A2N300 |
DELAY ON MAKE 300 SEC. |
|||||||
|
ICM |
MOR115A2N30 |
DELAY ON MAKE 30 SEC TIMER |
|||||||
|
ICM |
PTB01 |
ICM Probe |
|||||||
|
ICM |
PTB10 |
PROBE |
|||||||
|
ICM |
RSN20 |
STANDARD COIL SENSOR FOR CC750 |
|||||||
|
ICM |
SC045 |
TEMP STAT, CI ONLY/45 FIXED |
|||||||
|
ICM |
SC055 |
TEMP STAT, CI ONLY/55 FIXED |
|||||||
|
ICM |
SC060 |
TEMP STAT, HT ONLY/60 FIXED |
|||||||
|
ICM |
SC065 |
TEMP STAT,HT ONLY/65 FIXED |
|||||||
|
ICM |
SC070 |
TEMP STAT, HT ONLY/70 FIXED |
|||||||
|
ICM |
SC075 |
TEMP STAT, CI ONLY/75 FIXED |
|||||||
|
ICM |
SC1600L |
HEAT ONLY,W/O FAN SWTCH, BATT |
|||||||
|
ICM |
SC1600VL |
Heat Only,Non-Prog,Batter,Vert |
|||||||
|
ICM |
SC1800L |
HEAT ONLY, BATTERY |
|||||||
|
ICM |
SC1901L |
COOL ONLY,HARDWIRED |
|||||||
|
ICM |
SC1901 |
COOL ONLY, BATTERY,HARDWIRE |
|||||||
|
ICM |
SC2000L |
1Ht/1Cl 1StgHeatPmp Battery |
|||||||
|
ICM |
SC2001L |
1 STG HT/1 STG CL BACKLIGHT |
|||||||
|
ICM |
SC2010L |
1STG HT/CL OR HT PMP,BK LIGHT |
|||||||
|
ICM |
SC2201L |
2Ht/1Cl Non-Prog
Manual C/O |
|||||||
|
ICM |
SC2211L |
3-Ht/2-Cl,HeatPump,ManualC/O |
|||||||
|
ICM |
SC2311L |
2-Ht/1-Cl,HeatPump,ManC/O |
|||||||
|
ICM |
SC2311 |
Non-Prog
2-Heat 1-Cool T-Stat |
|||||||
|
ICM |
SC3000L |
7dayProg Ht/Cl,HtPmp,ManC/O |
|||||||
|
ICM |
SC3001L |
7Day prog
ht/cl Backlit |
|||||||
|
ICM |
SC3001 |
PRGRM/NON SS HT/CL OR HP, 24V |
|||||||
|
ICM |
SC3010L |
7DayProg,1H/1C,Man.C/O,Backlit |
|||||||
|
ICM |
SC3211L |
7-DayProg,2H/2C,HtPump,ManC/O |
|||||||
|
ICM |
SC4812 |
3-Ht/2-Cl,HtPump,Man/AutoC/O |
|||||||
|
ICM |
SC5011 |
PROGRAMABLE STAT HT/CL AUTO |
|||||||
|
ICM |
SC5211 |
2STAGE,7DAY,5-1-1,5-2,SMPL SET |
|||||||
|
ICM |
SC5811 |
2stage1H/1C,7-dayProg,Auto C/O |
|||||||
|
ICM |
SC5812 |
7 DAY,5-5-5,or 5-2PROGRAMMABLE |
|||||||
|
ICM |
UMSR-50 |
UnivMtrStartingRelay110-270vac |
|||||||
|
ICM |
UMSRE-50 |
UNIVERSAL POTENTIAL RELAY |
|||||||
|
|||||||||